RL series Reverse Osmosis System
The RL series reverse osmosis systems are designed for treating from wide range of water sources including municipal supplies, dam and river waters, bore and brackish water sources. These basic systems are designed to be simple to install, operate and require little maintenance. A membrane flush facility is standard and operates each time the system is started to assist with keeping the membranes clean. Continual monitoring of feedwater pressure, RO permeate quality and storage tank level is performed by PLC controller. ROTEK's Reverse Osmosis systems are capable of removing salts as well as other impurities such as bacteria, sugars, proteins, dyes and constituents having a molecular weight greater than 150-250 dalton.
Product Features:
* Schedule 80 rigid pipe work
* Stainless steel control valves and pump
* Programmable PLC controller
* Low feedwater pressure sensor
* Permeate quality sensor & conductivity display
* Storage tank level sensor input (24 VDC)
* Permeate and reject flow rotameters
* Adjustable pressure regulator valve
* Auto flush (optional with permeate water)
* Panel mount pressure gauges
* Electrical mimic panel with status indicators
* Electro-polished stainless steel frame
SpecificationsSpecifications \ Models | RL-2T | RL-2.5T | RL-3T | RL-4T | RL-6T | RL-9T | RL-12T |
Permeate Flow LPH | 2000 | 2500 | 3000 | 4000 | 6000 | 9000 | 12000 |
Module Qty & Size | (4), 4"x80" | (5), 4"x80" | (4), 4"x120" | (4), 4"x40" | (2), 8"x80" | (3), 8"x120" | (3), 8"x160" |
Nominal Recovery | 50-75% |
Motor (kw) | 0.75 | 2.25 | 2.25 | 2.25 | 3 | 3 | 3 |
Weight (kg) | 43 | 43 | 43 | 43 | 43 | 43 | 43 |
Dimension (mm) | 530 x 530 x 1150 |
Specifications \ Models | RL-16T | RL-20T | RL-24T | RL-30T | RL-35T | RL-45T | RL-50T |
Permeate Flow LPH | 16000 | 20000 | 24000 | 30000 | 35000 | 45000 | 50000 |
Module Qty & Size | (4), 8"x160" | (4), 8"x200" | (4), 8"x240" | (5), 8"x240" | (5), 8"x280" | (6), 8"x280" | (7), 8"x280" |
Nominal Recovery | 50-75% |
Motor (kw) | 0.75 | 2.25 | 2.25 | 2.25 | 3 | 3 | 3 |
Weight (kg) | 43 | 43 | 43 | 43 | 43 | 43 | 43 |
Dimension (mm) | 530 x 530 x 1150 |
Feed Water RequirmentspH: 3.0 : 10.0
TDS: < 2,000 ppm (choose BW systems when exceed)
Turbidity: < 1.0 NTU (required pre-treatment when exceed)
SDI: < 5.0 (required pre-treatment when exceed)
Hardness: < 50 ppm (required pre-treatment when exceed)
Residual Chlorine: < 0.1 ppm (required pre-treatment when exceed)
Feed water quality, pressures and flow rates have a significant impact on the performance of any reverse osmosis system. To ensure reliable and consistent long-term performance, it is important to supply feed water having the minimum specifications detailed below. If your feed water supply is marginal, you should consider using a feed water break tank and booster pump to supply the system.
|
|
|